ANALISIS KUALITAS AIR MINUM DAN KANDUNGAN LOGAM BERAT TIMBAL (Pb) PADA DEPOT AIR MINUM ISI ULANG (DAMIU) DI KOTA PALANGKA RAYA-KALIMATAN TENGAH

Authors

  • Dwi Hermayantiningsih Universitas Palangka Raya
  • Muh. Supwatul Hakim
  • Tety Wahyuningsih Manurung

DOI:

https://doi.org/10.36526/jc.v8i1.5945

Keywords:

air, timbal (Pb), air minum isi ulang

Abstract

An analysis of drinking water quality, including physical parameters such as TDS (Total Dissolved Solids), color, odor, and taste, as well as chemical parameters such as pH and lead ion content in refillable drinking water depots in Palangka Raya City, has been conducted. Drinking water requirements must comply with the Regulation of the Minister of Health of the Republic of Indonesia Number 2 of 2023 concerning the Implementation of Government Regulation Number 66 of 2014 regarding Environmental Health. The method throughout this investigation is laboratory experiment. Samples of refillable drinking water were obtained using a random sampling method at 9 different locations in Jekan Raya District. Based on the analysis of physical parameters including TDS, color, odor, and taste, the drinking water sample still meets drinking water quality standards. The results of pH measurements at 7 out of 9 sampling points showed that the pH values of 6.5-8.5 did not meet the quality standards. Analysis of lead (Pb) levels based on AAS showed that the Pb content in 9 samples was below the maximum permissible standard of 0.01 mg/L.

References

Artati, A. (2018) ‘Analisis Kadar Timbal (Pb) Pada Air yang Melalui Saluran Pipa Penyalur Perusahaan Daerah Air Minum (PDAM) Makassar’, Jurnal Media Analis Kesehatan, 1(1), pp. 47–55. Available at: https://doi.org/10.32382/mak.v1i1.152.

Hakim, M.S. et al. (2023) ‘Analisis Kadar Asiditas dan Alkalinitas pada Saluran Drainase Primer Pengeringan IV Bukit Keminting Kota Palangka Raya, Kalimantan Tengah’, Indonesian Journal Of Chemical Research [Preprint]. Available at: https://doi.org/10.20885/ijcr.vol8.iss1.art3.

Harsojo dan Darsono (2014) ‘Studi Kandungan Logam Berat dan Mikroba Pada Air Minum Isi Ulang Study of Heavy Metals and Microbes Content in Refill Drinking Water’, Ecolab, 8(2), pp. 53–96.

Hasrianti and Nurasia (2016) ‘Analisis Warna, Suhu, pH dan Salinitas Air Sumur Bor di Kota Palopo’, Jurnal Kesehatan Lingkungan Indonesia, 02(1), pp. 747–753.

Herman, H. (2019) ‘Analisis Kadar Timbal (Pb) Pada Air yang Melalui Saluran Pipa Penyalur Perusahaan Daerah Air Minum (PDAM) Makassar’, Jurnal Media Analis Kesehatan, 8(2), p. 91. Available at: https://doi.org/10.32382/mak.v8i2.848.

Kementerian Kesehatan (2023) ‘Permenkes No. 2 Tahun 2023’, Kemenkes Republik Indonesia, (55), pp. 1–175.

Kesumaningrum, F., Ismayanti, N.A. and Muhaimin, M. (2019) ‘Analisis Kadar Logam Fe, Cr, Cd dan Pb dalam Air Minum Isi Ulang Di Lingkungan Sekitar Kampus Universitas Islam Indonesia Yogyakarta Menggunakan Spektrofotometer Serapan Atom (SSA)’, IJCA (Indonesian Journal of Chemical Analysis), 2(01), pp. 41–46. Available at: https://doi.org/10.20885/ijca.vol2.iss1.art6.

Manurung, T.W. et al. (2023) ‘Studi Pengaruh Air Limbah Domestik Penduduk Jalan Lele Kota Palangka Raya Terhadap Kadar Asudutas dan AlkaliniTAS Badan Air Penerima’, Jurnal Jejaring Matematika dan Sains, 5(1), pp. 35–42.

Mujianto, B., Purwanti, A. and Rismini, S. (2015) ‘Kandungan Besi Air Sumur Di Perumahan Huma Akasia Jatiwarna-Pondok Melati, Bekasi’, Jurnal Ilmu dan Teknologi Kesehatan, 2(2), pp. 21–25.

Nuraini, Iqbal and Sabhan (2015) ‘Analisis Logam Berat dalam Air Minum Isi Ulang (AMIU) dengan Menggunakan Spektrofotometri Serapan Atom (SSA)’, Gravitasi, 14(1), pp. 36–43.

Pasaribu, M.H., Manurung, T.W. and Ariefin, M. (2023) ‘Kajian Kualitas Air Sumur Pada Permukiman Baru Kelurahan Jekan Raya Palangka Raya Serta Kaitannya Dengan Sumber Air Bersih Warga’, Jurnal Bakti untuk Negeri, 3(2), pp. 109–122. Available at: https://doi.org/10.36387/jbn.v3i2.1573.

Pulungan, S.A. and Away, Y. (2019) ‘Analisa Kualitas Air Minum Isi Ulang Ditanjung Pati’, LUMBUNG, 18(1), pp. 10–19. Available at: https://doi.org/10.32530/lumbung.v18i1.178.

Purba, I.G. (2015) ‘Pengawasan Terhadap Penyelenggaraan Depot Air Minum Dalam Menjamin Kualitas Air Minum Isi Ulang’, Jurnal Ilmu Kesehatan Masyarakat, 6, pp. 63–73.

Putri, R.Z. (2017) ‘Hubungan Konsentrasi Timbal dalam Air Perusahaan Daerah Air Minum (PDAM) dengan Kejadian Hipertensi di Desa Sijantang Koto Kecamatan Talawi Kota Sawahlunto (Skripsi)’, Fakultas Kedokteran Universitas Andalas [Preprint].

Rosita, N. (2014) ‘Analisis Kualitas Air Minum Isi Ulang Beberapa Depot Air Minum Isi Ulang (DAMIU) di Tangerang Selatan’, Jurnal Kimia VALENSI, pp. 134–141. Available at: https://doi.org/10.15408/jkv.v0i0.3611.

Sisca, V. (2016) ‘Penentuan Kualitas Air Minum Isi Ulang Terhadap Kandungan Nitrat, Besi, Mangan, Kekeruhan, pH, Bakteri E.coli dan Coliform.’, Chempublish, 1(2), pp. 21–31.

Sukoasih, A. and Widiyanto, T. (2017) ‘Hubungan Antara Suhu, pH dan Berbagai Variasi Jarak Dengan Kadar Timbal (Pb) Pada Badan Air Sungai Rompang dan Air Sumur Gali Industri Batik Sokaraja Tengah Tahun 2016’, Buletin Keslingmas, 36(4), pp. 360–368. Available at: https://doi.org/10.31983/keslingmas.v36i4.3115.

Suwarsito and Sarjanti, E. (2014) ‘Analisa Spasial Pencemaran Logam Berat Pada Sedimen Dan Biota Air Di Muara Sungai Serayu Kabupaten Cilacap’, Geoedukasi, III(1), pp. 30–37.

Walangitan (2016) ‘Gambaran Kualitas Air Minum Dari Depot Air Minum Isi Ulang di Kelurahan Ranotana-Weru dan Kelurahan Karombasan Selatan Menurut Parameter Mikrobiologi. : Volume IV Nomor 1’, Jurnal Kedokteran Komunitas dan Tropik, IV(1), pp. 49–58.

Published

2026-03-31

How to Cite

Hermayantiningsih, D., Hakim, M. S., & Manurung, T. W. (2026). ANALISIS KUALITAS AIR MINUM DAN KANDUNGAN LOGAM BERAT TIMBAL (Pb) PADA DEPOT AIR MINUM ISI ULANG (DAMIU) DI KOTA PALANGKA RAYA-KALIMATAN TENGAH. Jurnal Crystal : Publikasi Penelitian Kimia Dan Terapannya, 8(1), 7–14. https://doi.org/10.36526/jc.v8i1.5945